Datasheet:
Some dust extraction applications are too large for a downflow bench. For these much larger dust extraction applications we use Vertex, our modular cross-flow extraction system. Vertex draws large volumes of air sideways, past the operator, and into internal filters, returning clean air to the room. These modular systems can be installed together alongside our standard booth components to form a walk-in dust extraction booth.
The unique Vertex modular system allows for rapid build and configuration; or construction of large extracted walls in very short timescales.
Low energy fans allow us to move large volumes of air at low power. EC technology permits simple low voltage control, or central management. Single or three phase versions are available at no extra cost.
Controls.
Ranging from a simple on/off switch on a single unit to centrally controlled daisy chained systems for multiple installations. Speed control is available as a simple option. Every unit is fitted with a filter condition monitoring via a pressure loss gauge.
Vertex VA Modular cross-flow extraction systems offer eight different size options which can be configured to suit most application sizes.
Vertex systems can also be supplied in a number of styles to suit a wide range of applications.
Heavy Duty 2mm steel
Fully welded and powder coated
Can be used as a stand-alone dust extraction system
Combine multiple units with the VB booth system.
AVAILABLE SIZES for Vertex VA
MODEL
WIDTH
DEPTH
HEIGHT
VENTILATED AREA
V390-VA120618
1274
700
1760
1200x600
V390-VA121218
1274
700
1760
1200x1200
V390-VA180618
1874
700
1760
1800x600
V390-VA181218
1874
700
1760
1800x1200
V390-VA121224
1274
700
2465
1200x1200
V390-VA121824
1274
700
2465
1200x1800
V390-VA181224
1874
700
2465
1800x1200
V390-VA181824
1874
700
2465
1800x1800
AVAILABLE FILTERS for use with VA
Filters
FILTER CATEGORY
Pre
Final
APPLICATIONS
A - Non Sparking Dusts
G4
Aluminium - Plastics - Atmospheric dusts - Flour or similar - GRP - Airline cleaning of electronics
F – Fine Dusts
G4
F7
Carbon fibre finishing/sanding - Powder sampling - Other composites - Softwood dusts - Tool cleaning without RCS - Suitable for most general dust applications
B - Very Fine Dusts
G4
F9
Fingerprinting - Rapid prototyping - Model making - Conservation and restoration - Printer / copier toner cartridge recycling - Powder sampling - Some chemical dusts
L - HEPA Filtered
G4
H13
Pharmaceuticals - Hardwoods and MDF - Laboratory - Optical - Clean packing areas - Materials containing RCS - Hazardous dusts
C - Dust and Light Sparks
Spark
M6
Fettling - Sanding - Deburring - Dressing of welds
E - Low Volume Fume
G4
Carbon (450mm)
Solvents - Conformal coatings - Adhesives - Airbrushing - Cleaning fluids - Not for MEK
J - High Volume Fume
G4
Carbon (900mm)
Solvents - Conformal coatings - Adhesives - Airbrushing - Cleaning fluids - Not for MEK. Note - 960mm high with this filter configuration
R - Special Duty Fume
G4
Chemisorb
Formaldehyde - Nitrogen Dioxide - Sulphur Dioxide - Hydrogen Sulphide - MEK - See ‘E’ and ‘J’ configurations for other fume applications. Note - 960mm high with this filter configuration
S - Smoke and Fume
G4
F9
Soldering - Brazing - Conservation
Vertex VS Modular cross-flow extraction systems in Stainless steel offer eight different size options which can be configured to suit most application sizes.
Vertex systems can also be supplied in a number of styles to suit a wide range of applications.
Heavy Duty 2mm T304 Stainless Steel as standard or T316 optional.
For use in Cleanroom environments.
Combine multiple units with the VB booth system.
AVAILABLE SIZES for Vertex VS
MODEL
WIDTH
DEPTH
HEIGHT
VENTILATED AREA
V390-VS120618
1274
700
1760
1200x600
V390-VS121218
1274
700
1760
1200x1200
V390-VS180618
1874
700
1760
1800x600
V390-VS181218
1874
700
1760
1800x1200
V390-VS121224
1274
700
2465
1200x1200
V390-VS121824
1274
700
2465
1200x1800
V390-VS181224
1874
700
2465
1800x1200
V390-VS181824
1874
700
2465
1800x1800
AVAILABLE FILTERS for use with VS
Filters
FILTER CATEGORY
Pre
Final
APPLICATIONS
A - Non Sparking Dusts
G4
Aluminium - Plastics - Atmospheric dusts - Flour or similar - GRP - Airline cleaning of electronics
F – Fine Dusts
G4
F7
Carbon fibre finishing/sanding - Powder sampling - Other composites - Softwood dusts - Tool cleaning without RCS - Suitable for most general dust applications
B - Very Fine Dusts
G4
F9
Fingerprinting - Rapid prototyping - Model making - Conservation and restoration - Printer / copier toner cartridge recycling - Powder sampling - Some chemical dusts
L - HEPA Filtered
G4
H13
Pharmaceuticals - Hardwoods and MDF - Laboratory - Optical - Clean packing areas - Materials containing RCS - Hazardous dusts
C - Dust and Light Sparks
Spark
M6
Fettling - Sanding - Deburring - Dressing of welds
E - Low Volume Fume
G4
Carbon (450mm)
Solvents - Conformal coatings - Adhesives - Airbrushing - Cleaning fluids - Not for MEK
J - High Volume Fume
G4
Carbon (900mm)
Solvents - Conformal coatings - Adhesives - Airbrushing - Cleaning fluids - Not for MEK. Note - 960mm high with this filter configuration
R - Special Duty Fume
G4
Chemisorb
Formaldehyde - Nitrogen Dioxide - Sulphur Dioxide - Hydrogen Sulphide - MEK - See ‘E’ and ‘J’ configurations for other fume applications. Note - 960mm high with this filter configuration
S - Smoke and Fume
G4
F9
Soldering - Brazing - Conservation
Vertex VP Modular cross-flow extraction systems with Pulsed Cleaning offer four different size options which can be configured to suit most application sizes.
Vertex systems can also be supplied in a number of styles to suit a wide range of applications.
Heavy Duty 2mm steel
Fully welded and powder coated
For heavy duty applications where dust volumes overpower standard panel filters.
Can be used as a stand-alone dust extraction system
Combine multiple units with the VB booth system.
VPL Models include final HEPA in additional module.
AVAILABLE SIZES for Vertex VP
MODEL
WIDTH
DEPTH
HEIGHT
VENTILATED AREA
V390-VP121224
1274
2735
2735
1200x1400
V390-VPL121224
1274
700
2465
1200x1800
V390-VP181224
1874
700
2465
1800x1400
V390-VPL181224
1874
700
2735
1800x1400
AVAILABLE FILTERS for use with VP
Filters
FILTER CATEGORY
Pre
Final
APPLICATIONS
M - Stone Dust and Similar
F7
Stone, Aggregates, Tool Hire. Non explosive dusts only
N - Stone Dust and Similar
F7
H13
Stone, Aggregates, Tool Hire. Non explosive dusts only.
Possible Respiratory Crystalline Silica content
Vertex VX Modular cross-flow ATEX rated extraction systems with Pulsed Cleaning offer four different size options which can be configured to suit most application sizes.
Vertex systems can also be supplied in a number of styles to suit a wide range of applications.
Heavy Duty 2mm steel
Fully welded and powder coated
ATEX rated motor, forward curved.
Can be used as a stand-alone dust extraction system
Combine multiple units with the VB booth system.
VPL Models include final HEPA in additional module.
AVAILABLE SIZES for Vertex VX
MODEL
WIDTH
DEPTH
HEIGHT
VENTILATED AREA
V390-VX120618
1314
900
1760
1200x600
V390-VX120624
1274
900
2465
1200x600
V390-VX121224
1874
900
2465
1200x1200
V390-VX121831
1314
900
3170
1200x1800
V390-VX180618
1934
900
1760
1800x600
V390-VX180624
1934
900
2465
1800x600
V390-VX181224
1934
900
2465
1800x1200
V390-VX181831
1934
900
3170
1800x1800
AVAILABLE FILTERS for use with VX
Filters
FILTER CATEGORY
Pre
Final
APPLICATIONS
X - Stone Dust and Similar
G4
F9
Any non sparking dusts in zone 22 areas.
Y - Stone Dust and Similar
G4
H13
Any non sparking dusts in zone 22 areas.
Reviews
There are no reviews yet.
Be the first to review “Vertex – Modular Cross-flow System” Cancel reply
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Reviews
There are no reviews yet.